Written Estimate First
Nothing is repaired until you approve it
P1 is U-Line’s drain pump code. Water that can’t leave the machine ends up in the bin or on the floor, so it is worth acting on soon.
U-Line’s service manuals list P1 as “Pump Circuit open,” and the UHCP115 guide adds that it applies only to units with a drain pump. U-Line model numbers that contain CP or NP have a factory-installed drain pump. In the UOCP115 guide, U-Line explains that P1 creates a service notice when the drain line is restricted or the drain pump has failed. For owners, U-Line’s advice on standing water is to check that the drain line isn’t restricted, remove kinks and tight bends, and test the drain by pouring about half a gallon of water into the bin. Source: U-Line UOCP115 user guide (opens in a new tab).
Nothing is repaired until you approve it
Serving homes across Dallas–Fort Worth
90 days, 6 months on labor for members
Toward the repair if you go ahead
Open daily, 8–8
On older U-Line units, the ice maker can wear out to the point where the whole inside assembly needs replacing, not just one part. U-Line still makes a complete replacement ice maker assembly that fits many of the older models.
Not every one appears every time.
From the drain line back to the pump.
Turn the machine off before reaching behind or under it.
Follow the tube from the back of the unit and straighten any kink or tight bend. U-Line limits the pump’s lift to 10 feet.
Remove ice near the drain opening and wipe away any debris or scale you can see around it.
Pour about half a gallon of water into the bin, as U-Line suggests, and watch whether it leaves at a steady rate.
Schedule a repair if:
More help, including other U-Line codes:
Ice maker repairU-Line ice Maker dr error codeU-Line ice Maker E11 error codeU-Line ice Maker E12 error codeU-Line refrigerator Door Alert guideAll U-Line repairU-Line UOCP115 user guideWritten estimate first
We test the pump, its float and wiring, and the drain path to the house drain, then hand you a written price to approve. ALAS is independent and not a U-Line factory authorized servicer, so a machine still under U-Line’s warranty should go to U-Line first.

Get it fixed near you
If the safe checks above don't clear the code, our technicians can diagnose it and give you a written estimate first.
U-Line lists it as the pump circuit being open. It appears only on units with a drain pump, and U-Line ties it to a restricted drain line or a failed pump.
U-Line’s guides say model numbers containing CP or NP have a factory-installed pump. Models with NB in the number use a gravity drain.
It is safer to switch it off until the drain works, since water with nowhere to go can reach the cabinetry.
A pump that fails from a defect during the parts-and-labor term is a warranty repair through a U-Line factory authorized servicer (U-Line warranty (opens in a new tab)). Contact U-Line before booking anyone else.