Written Estimate First
Nothing is repaired until you approve it
The igniter does its job, the flame appears, and the moment you release the knob it dies. On a Bertazzoni range that is usually about how long the knob was held, and Bertazzoni explains why.
Bertazzoni gas burners carry a flame failure device: a thermocouple beside the burner that has to warm up before the gas valve will stay open on its own. Bertazzoni’s dual fuel range manual (part 3100296) tells owners to press in the knob, turn it counterclockwise to HIGH, and keep holding it in for 5 to 10 seconds after the burner ignites, because the thermocouple must be heated for a few seconds before the knob is released. Its US FAQ gives a similar instruction, keeping the knob turned with the flame on high for 4 to 5 seconds, and adds that burners will not all light in exactly the same time, since gas has to start flowing first. The manual also says the flame should burn all the way around the cap; if it does not, check that the cap sits correctly on its base and the ports are clear. Sources: Bertazzoni manual 3100296 (dealer copy (opens in a new tab)) and Bertazzoni FAQ (opens in a new tab).
Nothing is repaired until you approve it
Serving homes across Dallas–Fort Worth
90 days, 6 months on labor for members
Toward the repair if you go ahead
Open daily, 8–8
We recently repaired a Bertazzoni gas range with a failed pressure regulator. Every Bertazzoni gas range has to run with the regulator supplied with it, set for either natural gas or propane. Any adjustment or conversion should be done by a qualified technician.
Typically one burner, sometimes several.
Technique and cleaning first, then parts.
Try these with the burner cool and dry.
Press in, turn to HIGH and keep holding for 5 to 10 seconds after the flame appears, as the dual fuel range manual says, then release.
Lift the cap, make sure the burner parts are dry and the ports are open, and set the cap squarely back on its base.
The flame should ring the whole cap. A flame on only part of the burner points back to the cap or blocked ports.
Schedule a repair if:
More help, including other Bertazzoni codes:
Cooktop repairBertazzoni oven Not Heating guideAll Bertazzoni repairAtmos Energy: recognizing a gas leakBertazzoni dual fuel range manual 3100296Written estimate first
Our technician checks the thermocouple, the safety valve and gas delivery to that burner, and the replacement cost is agreed on paper beforehand. During Bertazzoni’s two-year parts and labor term, its own service line should be first. Any gas odor means getting out of the house and phoning 911 and Atmos Energy once outside.

Bertazzoni’s dual fuel range manual says 5 to 10 seconds after ignition; its US FAQ says to keep the flame on high for 4 to 5 seconds before releasing. Holding toward the longer end gives the thermocouple time to warm.
Bertazzoni’s FAQ explains that gas needs to get flowing before a burner ignites, so all burners will not light in exactly the same time. A short difference is normal.
Turn the knob off and let any gas clear before trying again. If there is a gas smell, stop: knobs off, everyone out, and the 911 and Atmos Energy calls happen from the yard.
Call Bertazzoni’s US service line first. Its FAQ describes a 2-year parts and labor warranty and warns that using an outside servicer makes the service cost yours (Bertazzoni FAQ (opens in a new tab)). Bertazzoni has not authorized ALAS to do its warranty work; we are the shop to phone after the two years have passed.
ALAS Appliance Services
Written Estimate First
Diagnostic Credited
Real Warranty
Based in Plano